Firewall Throughput
9Mpps
IPS Throughput
1.4Gbps
NGFW Throughput
1Gbps
Threat Protection Throughput
700Mbps
Application Control Throughput
1.8Gbps
IPsec VPN Throughput
6.5Gbps
SSL VPN Throughput
900Mbps
Firewall Latency
4μs
Concurrent Sessions ( TCP )
700,000
New Sessions/Second (TCP)
35,000
Interface
1. 1x USB Port
2. 1x Console Port
3. 2x GE RJ45 WAN Ports
4. 1x GE RJ45 DMZ Port
5. 2x GE RJ45 FortiLink Ports
6. 5x GE RJ45 Internal Ports
Local Storages
–
AC Power Supply
10.17 W / 12.43 W
Form Factor
Desktop
Variants
-
Intelligent Traffic Processing
L7 requests per second: 1M
L4 connections per second: 500K
L4 HTTP requests per second: 7M
Maximum L4 concurrent connections: 36M
Throughput: 80 Gbps/40 Gbps L4/L7
Hardware Offload SSL/TLS
Included: 21,000 TPS (2K keys)
Maximum: 21,000 TPS (2K keys)
22 Gbps bulk encryption*
FIPS SSL
N/A
Hardware Compression
N/A
Hardware DDoS Protection
40M SYN cookies per second
TurboFlex Performance Profiles
N/A
Software Compression
Included: 12 Gbps
Maximum: 12 Gbps
Software Architecture
64-bit TMOS
On-Demand Upgradable
Yes
Virtualization (Maximum Number of vCMP Guests)
N/A
Processor
Intel hex core
(total 12 hyperthreaded logical processor cores)
Memory
48 GB
Hard Drive
Two 1 TB drives (RAID 1) (10000s)
400 GB solid state drive (10050s)
Two 400 GB solid state drive (RAID1) (10055s)
Gigabit Ethernet CU Ports
Optional SFP
Gigabit Fiber Ports (SFP)
Optional SFP (SX or LX)
10 Gigabit Fiber Ports (SFP+)
16 SR or LR (sold separately, 2 SR included);
Optional 10G copper direct attach
40 Gigabit Fiber Ports (QSFP+)
2 SR4 (sold separately) (QSFP+ optical breakout cable
assemblies available to convert to 10 gigabit ports)
Power Supply
Dual 850W included (80 Plus Platinum efficiency), DC optional
Typical Consumption
320W (dual supply, 110V input)
Input Voltage
90–240 VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
1090 BTU/hour (dual supply, 110V input)
Dimensions
3.45” (8.76 cm) H x 17.3” (43.94 cm) W x 21.4” (54.36 cm) D
2U industry standard rack-mount chassis
Weight
43 lbs. (19.5 kg) (dual power supply)
Operating Temperature
32° to 104° F (0° to 40° C)
Operational Relative Humidity
5% to 85% at 40° C
Safety Agency Approval
UL 60950-1 2nd Edition; CAN/CSA C22.2 No. 60950-1-07
EN 60950-1:2006, 2nd Edition; IEC 60950-1:2006, 2nd
Edition
Evaluated to all CB Countries
Certifications/ Susceptibility Standards
EEN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006; EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A
VCCI Class A